{"created":"2023-06-20T15:12:36.071018+00:00","id":9400,"links":{},"metadata":{"_buckets":{"deposit":"01ae056d-601b-453e-9bd5-ef28491f576c"},"_deposit":{"created_by":3,"id":"9400","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"9400"},"status":"published"},"_oai":{"id":"oai:ynu.repo.nii.ac.jp:00009400","sets":["495:496"]},"author_link":["33129","34812","34813"],"item_2_biblio_info_8":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2016-07","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"98","bibliographicPageStart":"90","bibliographicVolumeNumber":"83","bibliographic_titles":[{"bibliographic_title":"Fire Safety Journal"}]}]},"item_2_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"This study focuses on the fire-suppression capabilities and corrosive properties of ferrocene dispersions. The motivation behind the present study was to develop a high-performance, phosphorus-free fire suppressant. Aqueous dispersions containing micron-sized ferrocene particles and surfactants were prepared using sonication techniques. In this study, Triton X-100 (TX), Noigen TDS-80 (NT), Tween 60 (T60), and Tween 80 (T80) were used as surfactants. Suppression experiments involving pool fires clearly indicated that aqueous ferrocene dispersions containing TX and micron-sized ferrocene with a d50=16.9 μm exhibit shorter extinguishing times than a conventional wet chemical. Corrosion trials using steel plates immersed in ferrocene dispersions containing TX confirmed that there was no pitting corrosion, implying that ferrocene dispersions containing TX do not present a corrosion risk.","subitem_description_type":"Abstract"}]},"item_2_publisher_35":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"Elsevier B.V."}]},"item_2_relation_13":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isVersionOf","subitem_relation_type_id":{"subitem_relation_type_id_text":"info:doi/10.1016/j.firesaf.2016.05.006","subitem_relation_type_select":"DOI"}}]},"item_2_rights_14":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"© 2016, Elsevier B.V. This manuscript version is made available under the CC-BY-NC-ND 4.0 license http://creativecommons.org/licenses/by-nc-nd/4.0/ "}]},"item_2_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"03797112","subitem_source_identifier_type":"ISSN"}]},"item_2_text_4":{"attribute_name":"著者所属","attribute_value_mlt":[{"subitem_text_value":"Department of Materials Science and Chemical Engineering, Faculty of Engineering, Yokohama National University"},{"subitem_text_value":"Department of Materials Science and Chemical Engineering, Faculty of Engineering, Yokohama National University"},{"subitem_text_value":"Department of Safety Management, Faculty of Environmental and Information Sciences, Yokohama National University"}]},"item_2_version_type_18":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_ab4af688f83e57aa","subitem_version_type":"AM"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Koshiba, Yusuke"}],"nameIdentifiers":[{"nameIdentifier":"33129","nameIdentifierScheme":"WEKO"},{"nameIdentifier":"60419273","nameIdentifierScheme":"e-Rad","nameIdentifierURI":"https://kaken.nii.ac.jp/ja/search/?qm=60419273"}]},{"creatorNames":[{"creatorName":"Okazaki, Shinji"}],"nameIdentifiers":[{"nameIdentifier":"34812","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Ohtani, Hideo"}],"nameIdentifiers":[{"nameIdentifier":"34813","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2018-11-08"}],"displaytype":"detail","filename":"Fire Saf J 83 (2016) 90-98.pdf","filesize":[{"value":"946.3 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"Fire Saf J 83 (2016) 90-98.pdf","url":"https://ynu.repo.nii.ac.jp/record/9400/files/Fire Saf J 83 (2016) 90-98.pdf"},"version_id":"280224a6-21a8-4408-9c52-34d5e59f9d4f"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Ferrocene powder","subitem_subject_scheme":"Other"},{"subitem_subject":"Fire suppression","subitem_subject_scheme":"Other"},{"subitem_subject":"Aqueous dispersion","subitem_subject_scheme":"Other"},{"subitem_subject":"Water mist","subitem_subject_scheme":"Other"},{"subitem_subject":"Additive","subitem_subject_scheme":"Other"},{"subitem_subject":"Extinguishing time","subitem_subject_scheme":"Other"},{"subitem_subject":"Fire-extinguishing agent","subitem_subject_scheme":"Other"},{"subitem_subject":"Corrosion","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Experimental investigation of the fire extinguishing capability of ferrocene-containing water mist","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Experimental investigation of the fire extinguishing capability of ferrocene-containing water mist"}]},"item_type_id":"2","owner":"3","path":["496"],"pubdate":{"attribute_name":"公開日","attribute_value":"2018-11-08"},"publish_date":"2018-11-08","publish_status":"0","recid":"9400","relation_version_is_last":true,"title":["Experimental investigation of the fire extinguishing capability of ferrocene-containing water mist"],"weko_creator_id":"3","weko_shared_id":3},"updated":"2023-06-20T19:33:23.606588+00:00"}