{"created":"2023-06-20T15:12:35.940088+00:00","id":9397,"links":{},"metadata":{"_buckets":{"deposit":"fc420eba-b997-4032-b0f3-3579910c60a9"},"_deposit":{"created_by":3,"id":"9397","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"9397"},"status":"published"},"_oai":{"id":"oai:ynu.repo.nii.ac.jp:00009397","sets":["495:496"]},"author_link":["33129","34803"],"item_2_biblio_info_8":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2016-05","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"16","bibliographicPageStart":"10","bibliographicVolumeNumber":"40","bibliographic_titles":[{"bibliographic_title":"Journal of Loss Prevention in the Process Industries"}]}]},"item_2_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"The objective of the present study was to explore the relationship between the dispersibility and fire-extinguishing capability of aqueous ferrocene dispersions containing gemini surfactants belonging to the same series, namely, olfin E1020, olfin PD 201, and surfynol 465. In this study, the dispersibility and ability to suppress pool fires were characterized by turbidity and extinguishing time, respectively. Ultrasonication enabled easy preparation of the aqueous dispersions of ferrocene powder containing the gemini surfactants. Visual observations and turbidity measurements clearly demonstrated that the order of dispersibility was as follows: ferrocene dispersion containing surfynol 465 ≥ ferrocene dispersion containing olfin E1020 > ferrocene dispersion containing olfin PD201. Fire suppression experiments indicated that the ferrocene diameter, in the ferrocene diameter range of 10.4–21.5 μm, negligibly influenced the extinguishing time. Furthermore, for the same ferrocene samples as were used for the turbidity measurements, the order of extinguishing ability was as follows: ferrocene dispersion containing surfynol 465 > ferrocene dispersion containing olfin E1020 > ferrocene dispersion containing olfin PD201; thus, the extinguishing ability was identical to the dispersibility order.","subitem_description_type":"Abstract"}]},"item_2_publisher_35":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"Elsevier B.V."}]},"item_2_relation_13":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isVersionOf","subitem_relation_type_id":{"subitem_relation_type_id_text":"info:doi/10.1016/j.jlp.2015.11.029","subitem_relation_type_select":"DOI"}}]},"item_2_rights_14":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"© 2015, Elsevier B.V. This manuscript version is made available under the CC-BY-NC-ND 4.0 license http://creativecommons.org/licenses/by-nc-nd/4.0/ "}]},"item_2_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"09504230","subitem_source_identifier_type":"ISSN"}]},"item_2_text_4":{"attribute_name":"著者所属","attribute_value_mlt":[{"subitem_text_value":"Department of Materials Science and Chemical Engineering, Faculty of Engineering, Yokohama National University"},{"subitem_text_value":"Department of Safety Management, Faculty of Environmental and Information Sciences, Yokohama National University"}]},"item_2_version_type_18":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_ab4af688f83e57aa","subitem_version_type":"AM"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Koshiba, Yusuke"}],"nameIdentifiers":[{"nameIdentifier":"33129","nameIdentifierScheme":"WEKO"},{"nameIdentifier":"60419273","nameIdentifierScheme":"e-Rad","nameIdentifierURI":"https://kaken.nii.ac.jp/ja/search/?qm=60419273"}]},{"creatorNames":[{"creatorName":"Otani, Hideo"}],"nameIdentifiers":[{"nameIdentifier":"34803","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2018-11-08"}],"displaytype":"detail","filename":"J Loss Prev Process Ind 40 (2016) 10-16.pdf","filesize":[{"value":"719.5 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"J Loss Prev Process Ind 40 (2016) 10-16.pdf","url":"https://ynu.repo.nii.ac.jp/record/9397/files/J Loss Prev Process Ind 40 (2016) 10-16.pdf"},"version_id":"0912d46b-560e-4a94-9e7d-ec5ea322f8d6"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Ferrocene","subitem_subject_scheme":"Other"},{"subitem_subject":"Fire extinguishing agent","subitem_subject_scheme":"Other"},{"subitem_subject":"Aqueous dispersion","subitem_subject_scheme":"Other"},{"subitem_subject":"Water mist; Gemini surfactant","subitem_subject_scheme":"Other"},{"subitem_subject":"Additive","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Extinguishing pool fires with aqueous ferrocene dispersions containing gemini surfactants","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Extinguishing pool fires with aqueous ferrocene dispersions containing gemini surfactants"}]},"item_type_id":"2","owner":"3","path":["496"],"pubdate":{"attribute_name":"公開日","attribute_value":"2018-11-08"},"publish_date":"2018-11-08","publish_status":"0","recid":"9397","relation_version_is_last":true,"title":["Extinguishing pool fires with aqueous ferrocene dispersions containing gemini surfactants"],"weko_creator_id":"3","weko_shared_id":3},"updated":"2023-06-20T19:33:16.208371+00:00"}