{"created":"2023-06-20T15:09:23.509391+00:00","id":5324,"links":{},"metadata":{"_buckets":{"deposit":"8e9a5a9e-ba0f-40ab-bb23-458cfd8b894f"},"_deposit":{"created_by":3,"id":"5324","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"5324"},"status":"published"},"_oai":{"id":"oai:ynu.repo.nii.ac.jp:00005324","sets":["500:504:521:539"]},"author_link":["24916","24915","24919","24913","24918","24917","24914","24912"],"item_6_alternative_title_21":{"attribute_name":"その他のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"Continuous Treatment on Dioxins of EP Ash from a MSW Incineration Plant."}]},"item_6_biblio_info_8":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1989-12","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1","bibliographicPageEnd":"47","bibliographicPageStart":"43","bibliographicVolumeNumber":"16","bibliographic_titles":[{"bibliographic_title":"横浜国立大学環境科学研究センター紀要 = Bulletin of the Institute of Environmental Science and Technology, Yokohama National University"}]}]},"item_6_description_17":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_description":"application/pdf","subitem_description_type":"Other"}]},"item_6_description_42":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"subitem_description":"postprint","subitem_description_type":"Other"}]},"item_6_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"The fact that the high temperature treatment of EP ash using the stainless seal tube was effective to control the chlorinated compounds had been reported in the preceding paper,1988. On the basis of this result, the continuous treatment system was designed and tested, and then its possibility of the practical application in the MSW incineration plant was investigated. The destruction efficiency of PCDD and PCDF in EP ash depended on the conditions of temperature and residual time. It was confirmed that in this equipment almost 100% destruction was obtained at about 500℃ and for a few minutes.","subitem_description_type":"Abstract"}]},"item_6_full_name_2":{"attribute_name":"著者(ヨミ)","attribute_value_mlt":[{"nameIdentifiers":[{}],"names":[{"name":"ハナイ, ヨシミチ"}]},{"nameIdentifiers":[{}],"names":[{"name":"カトウ, タツオ"}]}]},"item_6_full_name_3":{"attribute_name":"著者別名","attribute_value_mlt":[{"nameIdentifiers":[{}],"names":[{"name":"Ok, Gon"}]},{"nameIdentifiers":[{}],"names":[{"name":"Hanai, Yoshimichi"}]},{"nameIdentifiers":[{}],"names":[{"name":"Katou, Tatsuo"}]}]},"item_6_publisher_35":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"横浜国立大学環境科学研究センター"}]},"item_6_source_id_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AN00246482","subitem_source_identifier_type":"NCID"}]},"item_6_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0286584X","subitem_source_identifier_type":"ISSN"}]},"item_6_text_4":{"attribute_name":"著者所属","attribute_value_mlt":[{"subitem_text_value":"横浜国立大学環境科学研究センター環境基礎工学研究室 = Department of Environmental Engineering Science, Institute of Environmental Science and Technology, Yokohama National University"},{"subitem_text_value":"横浜国立大学環境科学研究センター環境基礎工学研究室 = Department of Environmental Engineering Science, Institute of Environmental Science and Technology, Yokohama National University"},{"subitem_text_value":"横浜国立大学環境科学研究センター環境基礎工学研究室 = Department of Environmental Engineering Science, Institute of Environmental Science and Technology, Yokohama National University"}]},"item_6_version_type_18":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"玉, 坤"}],"nameIdentifiers":[{"nameIdentifier":"24912","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"花井, 義道"}],"nameIdentifiers":[{"nameIdentifier":"24913","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"加藤, 龍夫"}],"nameIdentifiers":[{"nameIdentifier":"24914","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2016-09-20"}],"displaytype":"detail","filename":"2008yoko1989_07.pdf","filesize":[{"value":"267.9 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"2008yoko1989_07.pdf","url":"https://ynu.repo.nii.ac.jp/record/5324/files/2008yoko1989_07.pdf"},"version_id":"2cdf1823-e231-401b-8797-db267dda06e9"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"都市ごみ焼却施設EP灰中ダイオキシン類の連続処理","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"都市ごみ焼却施設EP灰中ダイオキシン類の連続処理"}]},"item_type_id":"6","owner":"3","path":["539"],"pubdate":{"attribute_name":"公開日","attribute_value":"2010-05-11"},"publish_date":"2010-05-11","publish_status":"0","recid":"5324","relation_version_is_last":true,"title":["都市ごみ焼却施設EP灰中ダイオキシン類の連続処理"],"weko_creator_id":"3","weko_shared_id":-1},"updated":"2023-06-20T21:07:13.838642+00:00"}