ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 05 工学研究院・理工学府・理工学部
  2. 5-1 学術雑誌論文

Three-dimensional radiation dosimetry of carbon ion beams using surfactant hydrogels: Fundamental investigation

http://hdl.handle.net/10131/0002001353
http://hdl.handle.net/10131/0002001353
91481cb2-41ca-4019-aabc-c47f6ac95199
名前 / ファイル ライセンス アクション
Medical Medical Physics - 2024 - Toyohara - Three‐dimensional radiation dosimetry of carbon ion beams using surfactant hydrogels .pdf (3.2 MB)
license.icon
Item type 学術雑誌論文 / Journal Article(1)
公開日 2024-10-22
タイトル
タイトル Three-dimensional radiation dosimetry of carbon ion beams using surfactant hydrogels: Fundamental investigation
言語 en
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 open access
アクセス権URI http://purl.org/coar/access_right/c_abf2
著者 Toyohara, Masumitsu

× Toyohara, Masumitsu

en Toyohara, Masumitsu
Research Initiative and Promotion Organization, Yokohama National University

Search repository
Kusano, Yohsuke

× Kusano, Yohsuke

e-Rad_Researcher 40619665

en Kusano, Yohsuke
Kanagawa Cancer Center

Search repository
Kobayashi, Norihisa

× Kobayashi, Norihisa

en Kobayashi, Norihisa
Department of Chemistry and Life Science, Yokohama National University

Search repository
Gotoh, Hiroaki

× Gotoh, Hiroaki

e-Rad_Researcher 80635235

en Gotoh, Hiroaki
Department of Chemistry and Life Science, Yokohama National University

Search repository
Wada, Satoshi

× Wada, Satoshi

en Wada, Satoshi
Toshiba Energy Systems & Solutions Corporation

Search repository
抄録
内容記述タイプ Abstract
内容記述 Background
In carbon ion radiotherapy, accurate measurement of the three-dimensional (3D) absorbed dose distribution is critical for effectively targeting tumors. Although micellar gel dosimeters exhibit considerable potential for measuring 3D absorbed dose distributions, few studies have focused on radiotherapy using carbon ion beams.

Purpose
This study investigated the applicability of the surfactant hydrogel dosimeter (SHD), a micellar gel dosimeter, to measuring a 3D dose absorbed through carbon ion beam irradiation.

Methods
A cubic target region of 34 mm per side was established at a depth of 46 mm below the upper surface of an SHD specimen. Scanning irradiation was performed using a pencil beam of carbon ions at the Ion-beam Radiation Oncology Center in Kanagawa (“i-ROCK”), Japan, under irradiation conditions set by the treatment planning system (“Monaco for Carbon”, Ver. 5.20, Elekta AB, Sweden) to create a spread-out Bragg peak within the target. The physical dose was set to 10 Gy at the isocenter, situated at the center of the target. The SHD responsiveness was measured twice using optical computed tomography (CT) (“Vista 15”, Modus Medical Devices, Canada) for three irradiated specimens, and six types of measured optical attenuation coefficient (OAC) were obtained. To assess whether the OAC represented the absorbed dose expected in the treatment plan, we compared the relative distribution of the OAC and that of the absorbed dose. Relative fraction (RF) was used to measure the difference between the relative value of the OAC and that of the absorbed dose. Moreover, the distribution of OH radical (•OH) concentration obtained by Monte Carlo simulation (“PHITS” ver. 3.24 JAEA, Japan) and that of the OAC were compared.

Results
In the direction of beam travel, the relative distribution of the OAC was lower than that of the absorbed dose. This discrepancy could be attributed to a decrease in the concentration of •OH produced by irradiation owing to the recombination reaction, which does not accurately reflect the absorbed dose. By contrast, the distributions in the plane perpendicular to the beam travel were consistent. The RF increased from ± 3% to ± 13% along the beam travel direction. The small RF in the plane perpendicular to the beam travel could be attributed to the constant distribution of linear energy transfer, regardless of the irradiation position, and the generation of radicals proportionally to the absorbed dose. The increase in RF along the beam travel direction was ascribed to ring artifacts in the irradiated region.

Conclusion
The measurement of the absorbed dose distribution in the beam travel direction should be improved. The observed discrepancy is attributed to the reduced reactivity of the SHD due to a high liner energy transfer near the Bragg peak. However, the absorbed dose distribution can be effectively evaluated in the plane perpendicular to the direction of beam travel.
言語 en
書誌情報 en : Medical Physics

巻 Early Access, ページ数 17, 発行日 2024-10-09
ISSN
収録物識別子タイプ PISSN
収録物識別子 00942405
書誌レコードID
収録物識別子タイプ NCID
収録物識別子 AA00727671
DOI
関連タイプ isIdenticalTo
識別子タイプ DOI
関連識別子 https://doi.org/10.1002/mp.17433
権利
言語 en
権利情報Resource https://creativecommons.org/licenses/by-nc/4.0/
権利情報 Creative Commons Attribution-NonCommercial 4.0 International
著者版フラグ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
出版者
出版者 American Association of Physicists in Medicine
出版者
出版者 Wiley
戻る
0
views
See details
Views

Versions

Ver.1 2024-10-22 05:02:28.626071
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3