{"_buckets": {"deposit": "8c705146-4e4e-441d-a7f0-3f82b6775815"}, "_deposit": {"created_by": 3, "id": "497", "owners": [3], "pid": {"revision_id": 0, "type": "depid", "value": "497"}, "status": "published"}, "_oai": {"id": "oai:ynu.repo.nii.ac.jp:00000497", "sets": ["81"]}, "author_link": ["3618", "3621", "3622", "3614", "3619", "3620", "3617", "3616", "3615"], "item_6_alternative_title_21": {"attribute_name": "その他のタイトル", "attribute_value_mlt": [{"subitem_alternative_title": "A study of thermal storage management and control in the human body associated with physical exercise : Possibility of predicting the elevation in body temperature by ergometer exercise and controlling of the body temperature regulation by using water-cooling systems when wearing firefighter suits"}]}, "item_6_biblio_info_8": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2012-02-29", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "14", "bibliographicPageEnd": "8", "bibliographicPageStart": "1", "bibliographic_titles": [{"bibliographic_title": "横浜国立大学教育人間科学部紀要IV(自然科学)"}]}]}, "item_6_description_17": {"attribute_name": "フォーマット", "attribute_value_mlt": [{"subitem_description": "application/pdf", "subitem_description_type": "Other"}]}, "item_6_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Firefighter suits are air-tight clothes resistant to flame and radiant heat. It is therefore important to release the metabolic heat of the human body when wearing them. In this study, we attempted to control the body temperature by using water-cooling systems, and to predict the rise in body temperature while exercising wearing firefighter suits. As a result, With the bicycle ergometer exercise experiments wearing firefighter suits under high temperature(30 ℃ ), it was possible to estimate the degree of body-temperature elevation of the subject from his metabolic rate during the exercise. In controlling the body temperature using water-cooling systems, we recognized the need to ensure sufficient cooling capacity in relation to the amount of heat loss. Since it was estimated from past studies that the subject\u0027s comfort would be impaired if the refrigerant is uncontrollable, we found it important to control the body temperature with skin temperature sensor feedback and computer control.", "subitem_description_type": "Abstract"}, {"subitem_description": "消防員装具は、炎や輻射熱に対応するので密閉衣服となる.従って,人体の代謝熱を放出することが重要である.本研究において,我々は消防員装具着用時の運動負荷に伴う体温上昇を予測するとともに、水冷却システムで体温上昇を制御しようと試みた.その結果,高温条件下(30℃),消防員装具着用時における自転車エルゴ・メーター運動の実験では、運動時の代謝量から被験者の体温度上昇が推定可能であった。また,水冷による体温コントロールでは、熱損失の関係から十分な冷却能力を確保する必要性を認識した。さらに過去の研究結果から、総合的に考えると冷媒を制御できない場合には、対象者の快適性を損なうと推定されたので、皮膚温度センサーからのフィードバックやコンピュータによる体温制御が重要と考えた。", "subitem_description_type": "Abstract"}]}, "item_6_full_name_2": {"attribute_name": "著者(ヨミ)", "attribute_value_mlt": [{"nameIdentifiers": [{"nameIdentifier": "3617", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Monobe, Hirofumi"}]}, {"nameIdentifiers": [{"nameIdentifier": "3618", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Murayama, Masaki"}]}, {"nameIdentifiers": [{"nameIdentifier": "3619", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Ikuno, Harumi"}]}]}, "item_6_full_name_3": {"attribute_name": "著者別名", "attribute_value_mlt": [{"nameIdentifiers": [{"nameIdentifier": "3620", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "モノベ, ヒロフミ"}]}, {"nameIdentifiers": [{"nameIdentifier": "3621", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "ムラヤマ, マサキ"}]}, {"nameIdentifiers": [{"nameIdentifier": "3622", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "イクノ, ハルミ"}]}]}, "item_6_publisher_35": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "横浜国立大学教育人間科学部"}]}, "item_6_source_id_11": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_source_identifier": "AA11311937", "subitem_source_identifier_type": "NCID"}]}, "item_6_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "13444646", "subitem_source_identifier_type": "ISSN"}]}, "item_6_text_4": {"attribute_name": "著者所属", "attribute_value_mlt": [{"subitem_text_value": "横浜国立大学 教育人間科学部 准教授 Yokohama National University"}, {"subitem_text_value": "社団法人 日本船舶品質管理協会 製品安全評価センター Research Institute of Marine Engineering"}, {"subitem_text_value": "東京学芸大学 教育学部 教授 Tokyo Gakugei University"}]}, "item_6_version_type_18": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "物部, 博文"}], "nameIdentifiers": [{"nameIdentifier": "3614", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "村山, 雅己"}], "nameIdentifiers": [{"nameIdentifier": "3615", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "生野, 晴美"}], "nameIdentifiers": [{"nameIdentifier": "3616", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2016-09-15"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "01monobe.pdf", "filesize": [{"value": "2.2 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 2200000.0, "url": {"label": "01monobe.pdf", "url": "https://ynu.repo.nii.ac.jp/record/497/files/01monobe.pdf"}, "version_id": "b4efe1e8-6a5e-4ec3-af43-cbcad61fd25f"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "fire-fighting operation", "subitem_subject_scheme": "Other"}, {"subitem_subject": "heatstroke", "subitem_subject_scheme": "Other"}, {"subitem_subject": "countermeasure to heat stress", "subitem_subject_scheme": "Other"}, {"subitem_subject": "water-cooling clothes", "subitem_subject_scheme": "Other"}, {"subitem_subject": "消防活動", "subitem_subject_scheme": "Other"}, {"subitem_subject": "熱中症", "subitem_subject_scheme": "Other"}, {"subitem_subject": "ヒートストレスの対処", "subitem_subject_scheme": "Other"}, {"subitem_subject": "水冷服", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "運動に伴う人体の蓄熱管理に関する研究:消防服着用時の体温上昇の予測と水冷による体温制御の可能性", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "運動に伴う人体の蓄熱管理に関する研究:消防服着用時の体温上昇の予測と水冷による体温制御の可能性"}]}, "item_type_id": "6", "owner": "3", "path": ["81"], "permalink_uri": "http://hdl.handle.net/10131/8138", "pubdate": {"attribute_name": "公開日", "attribute_value": "2012-09-10"}, "publish_date": "2012-09-10", "publish_status": "0", "recid": "497", "relation": {}, "relation_version_is_last": true, "title": ["運動に伴う人体の蓄熱管理に関する研究:消防服着用時の体温上昇の予測と水冷による体温制御の可能性"], "weko_shared_id": -1}
運動に伴う人体の蓄熱管理に関する研究:消防服着用時の体温上昇の予測と水冷による体温制御の可能性
http://hdl.handle.net/10131/8138
http://hdl.handle.net/10131/8138e81c589d-5cff-4aa8-884f-3d4deb1a8426
名前 / ファイル | ライセンス | アクション |
---|---|---|
01monobe.pdf (2.2 MB)
|
|
Item type | 紀要論文 / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2012-09-10 | |||||
タイトル | ||||||
タイトル | 運動に伴う人体の蓄熱管理に関する研究:消防服着用時の体温上昇の予測と水冷による体温制御の可能性 | |||||
言語 | ||||||
言語 | jpn | |||||
キーワード | ||||||
主題 | fire-fighting operation | |||||
キーワード | ||||||
主題 | heatstroke | |||||
キーワード | ||||||
主題 | countermeasure to heat stress | |||||
キーワード | ||||||
主題 | water-cooling clothes | |||||
キーワード | ||||||
主題 | 消防活動 | |||||
キーワード | ||||||
主題 | 熱中症 | |||||
キーワード | ||||||
主題 | ヒートストレスの対処 | |||||
キーワード | ||||||
主題 | 水冷服 | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | departmental bulletin paper | |||||
著者 |
物部, 博文
× 物部, 博文× 村山, 雅己× 生野, 晴美 |
|||||
著者(ヨミ) | ||||||
識別子Scheme | WEKO | |||||
識別子 | 3617 | |||||
姓名 | Monobe, Hirofumi | |||||
著者(ヨミ) | ||||||
識別子Scheme | WEKO | |||||
識別子 | 3618 | |||||
姓名 | Murayama, Masaki | |||||
著者(ヨミ) | ||||||
識別子Scheme | WEKO | |||||
識別子 | 3619 | |||||
姓名 | Ikuno, Harumi | |||||
著者別名 | ||||||
識別子Scheme | WEKO | |||||
識別子 | 3620 | |||||
姓名 | モノベ, ヒロフミ | |||||
著者別名 | ||||||
識別子Scheme | WEKO | |||||
識別子 | 3621 | |||||
姓名 | ムラヤマ, マサキ | |||||
著者別名 | ||||||
識別子Scheme | WEKO | |||||
識別子 | 3622 | |||||
姓名 | イクノ, ハルミ | |||||
著者所属 | ||||||
横浜国立大学 教育人間科学部 准教授 Yokohama National University | ||||||
著者所属 | ||||||
社団法人 日本船舶品質管理協会 製品安全評価センター Research Institute of Marine Engineering | ||||||
著者所属 | ||||||
東京学芸大学 教育学部 教授 Tokyo Gakugei University | ||||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Firefighter suits are air-tight clothes resistant to flame and radiant heat. It is therefore important to release the metabolic heat of the human body when wearing them. In this study, we attempted to control the body temperature by using water-cooling systems, and to predict the rise in body temperature while exercising wearing firefighter suits. As a result, With the bicycle ergometer exercise experiments wearing firefighter suits under high temperature(30 ℃ ), it was possible to estimate the degree of body-temperature elevation of the subject from his metabolic rate during the exercise. In controlling the body temperature using water-cooling systems, we recognized the need to ensure sufficient cooling capacity in relation to the amount of heat loss. Since it was estimated from past studies that the subject's comfort would be impaired if the refrigerant is uncontrollable, we found it important to control the body temperature with skin temperature sensor feedback and computer control. | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | 消防員装具は、炎や輻射熱に対応するので密閉衣服となる.従って,人体の代謝熱を放出することが重要である.本研究において,我々は消防員装具着用時の運動負荷に伴う体温上昇を予測するとともに、水冷却システムで体温上昇を制御しようと試みた.その結果,高温条件下(30℃),消防員装具着用時における自転車エルゴ・メーター運動の実験では、運動時の代謝量から被験者の体温度上昇が推定可能であった。また,水冷による体温コントロールでは、熱損失の関係から十分な冷却能力を確保する必要性を認識した。さらに過去の研究結果から、総合的に考えると冷媒を制御できない場合には、対象者の快適性を損なうと推定されたので、皮膚温度センサーからのフィードバックやコンピュータによる体温制御が重要と考えた。 | |||||
書誌情報 |
横浜国立大学教育人間科学部紀要IV(自然科学) 号 14, p. 1-8, 発行日 2012-02-29 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 13444646 | |||||
書誌レコードID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AA11311937 | |||||
フォーマット | ||||||
内容記述タイプ | Other | |||||
内容記述 | application/pdf | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
その他のタイトル | ||||||
その他のタイトル | A study of thermal storage management and control in the human body associated with physical exercise : Possibility of predicting the elevation in body temperature by ergometer exercise and controlling of the body temperature regulation by using water-cooling systems when wearing firefighter suits | |||||
出版者 | ||||||
出版者 | 横浜国立大学教育人間科学部 |